Agreement between two plasma bicarbonate assays in critically ill patients
1Department of Anaesthesia, Austin and Repatriation Medical Centre, Heidelberg, Victoria.
Plasma bicarbonate measurements using the Henderson-Hasselbalch equation may be unreliable in critically ill patients. A study found poor agreement between calculated and enzymatic bicarbonate assays, highlighting potential clinical concerns.
Area of Science:
- Clinical Chemistry
- Critical Care Medicine
- Biomedical Engineering
Background:
- Plasma bicarbonate concentration is a key indicator of acid-base balance.
- The Henderson-Hasselbalch equation is commonly used for its calculation, but its reliability is questioned in critically ill patients.
- Discrepancies in bicarbonate measurement can impact clinical decision-making.
Purpose of the Study:
- To evaluate the agreement between two commonly used plasma bicarbonate assays in critically ill patients.
- To compare bicarbonate measurements derived from the Henderson-Hasselbalch equation with those from a spectrophotometric enzymatic technique.
- To determine the clinical significance of any observed discrepancies.
Main Methods:
- A comparative study design was employed using routine daily blood samples from critically ill patients.
- Paired arterial blood samples were analyzed concurrently using two distinct bicarbonate measurement methods.
- Bland-Altman analysis was utilized to assess the agreement and quantify bias between the two assays.
Main Results:
- A significant bias of -1.6 mmol/l (95% CI: -1.2 to -2.0 mmol/l) was observed when comparing the enzymatic method to the calculated method.
- The limits of agreement ranged from -5.85 mmol/l to 2.65 mmol/l, indicating substantial variability.
- The study revealed poor agreement between the two plasma bicarbonate assays.
Conclusions:
- The findings indicate poor agreement between calculated and enzymatic plasma bicarbonate assays in critically ill patients.
- This discrepancy holds clinical importance, potentially affecting patient management and treatment strategies.
- Further research is recommended to investigate the underlying causes of this unreliability and to improve bicarbonate measurement accuracy.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Roles of Electrolytes: Chloride and Bicarbonate
Conditions such as hypochloremia can arise from insufficient chloride reabsorption by the kidneys, often compounded by extended bouts of diarrhea, vomiting, or...
Bicarbonate-Carbonic Acid Buffer
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...