New approaches to noninvasive assessment of pulmonary artery pressure
M M Mirrakhimov1, A M Tenenbaum, I K Moldotashev
1Department of Valvular Heart Disease and Heart Failure, Kirghiz Institute of Cardiology, Bishkek, Kyrgyzstan.
Abstract:
Direct measurement of pulmonary artery pressure (PAP) was performed in 36 patients; right ventricular (RV) isovolumic relaxation time (IRT) and RV systolic output acceleration time (AcT) values were assessed by pulsed Doppler and 2-M echocardiography. There was a fairly good correlation between RV IRT and systolic PAP (r = 0.898; SEE = 7.8 mmHg) and a somewhat weaker one between RV AcT and systolic PAP (r = -0.880; SEE = 8.37 mmHg). Correlation coefficients were the highest between systolic PAP and the [formula: see text] (r = 0.972; SEE = 4.14), and also between mean PAP and the 10-RV AcT/100 predictor: y = 158x + 6.7 (r = 0.951; SEE = 3.48 mmHg). With +/- 5 mmHg deviations, systolic PAP measurements were accurate in 78% and those of mean PAP in 98% of the patients. The double-blind assessment of the reproducibility of the suggested noninvasive PAP measurement was performed in 18 subsequent patients; the interstudy variability of the measurement was 0.88 +/- 0.94 mmHg and 1.22 +/- 1.23 mmHg (p > 0.05), whereas interobserver variability was 1.90 +/- 1.70 mmHg and 1.67 +/- 1.63 mmHg, respectively (p > 0.05). Thus, a combined use of the most informative intervals of RV cycle--IRT and AcT--contributes to the accuracy of noninvasive PAP measurement.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation