Related Experiment Video
Updated: Oct 13, 2026

Imaging Odor-Evoked Activities in the Mouse Olfactory Bulb using Optical Reflectance and Autofluorescence Signals
Published on: October 31, 2011
MRI detection of olfactory bulb and tract
Abstract:
Thirty healthy volunteers underwent MRI with 3D MP-RAGE, 3D CISS and 2D turbo spin echo sequences to compare the detectability of olfactory fibers, bulb, tract, and sulcus. The overall detectability was slightly better using MP-RAGE compared with CISS. Both 3D sequences were superior to 2D turbo spin echo. We therefore recommend including the MP-RAGE sequence in an MR imaging protocol of the olfactory nerve.
Insights
The 3D MP-RAGE MRI sequence slightly improved the detection of olfactory nerve structures compared to 3D CISS. Both 3D methods outperformed 2D turbo spin echo for visualizing the olfactory system.
Area of Science:
- Neuroimaging
- Radiology
- Anatomy
Background:
- Accurate visualization of the olfactory system is crucial for diagnosing olfactory disorders.
- Magnetic Resonance Imaging (MRI) offers non-invasive methods for anatomical assessment.
- Optimizing MRI sequences is essential for enhancing the detectability of delicate neural structures.
Purpose of the Study:
- To compare the efficacy of different MRI sequences in visualizing olfactory nerve fibers, bulb, tract, and sulcus.
- To determine the optimal MRI sequence for olfactory system imaging.
Main Methods:
- Thirty healthy volunteers participated in the study.
- MRI scans were acquired using 3D Magnetization Prepared Rapid Acquisition Gradient Echo (MP-RAGE), 3D Constructive Interference in Steady State (CISS), and 2D Turbo Spin Echo (TSE) sequences.
- Detectability of olfactory nerve components was assessed across the different sequences.
Main Results:
- The 3D MP-RAGE sequence demonstrated slightly better overall detectability of olfactory structures compared to the 3D CISS sequence.
- Both 3D MRI sequences (MP-RAGE and CISS) were found to be superior to the 2D TSE sequence in visualizing the olfactory system.
- Specific components like olfactory fibers, bulb, tract, and sulcus showed varying degrees of clarity across sequences.
Conclusions:
- The 3D MP-RAGE sequence is recommended for inclusion in MRI protocols aimed at imaging the olfactory nerve.
- Advanced 3D MRI techniques offer significant advantages over conventional 2D sequences for detailed olfactory system visualization.
- Further research may explore the clinical utility of MP-RAGE in patients with olfactory dysfunction.
Related Concept Videos
Olfactory Receptors: Location and Structure
Olfaction
The olfactory receptors are embedded in the cilia of the...
Physiology of Smell and Olfactory Pathway
The olfactory...

