A new method for calibrating indicator dilution curves.

J Boyle, P Diamond

    Journal of Applied Physiology
    |March 1, 1975
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The National Audit of Metastatic Breast Cancer (NAoMe): Sharing Key Findings and Recommendations From the 2025 State of the Nation Report.

    Clinical oncology (Royal College of Radiologists (Great Britain))·2026
    Same author

    Hospital Factors Influencing the Mobility of Patients for Systemic Therapies in Breast and Bowel Cancer in the Metastatic Setting: A National Population-based Evaluation.

    Clinical oncology (Royal College of Radiologists (Great Britain))·2024
    Same author

    Progress in High-Speed Spin Testing of Superconducting Wire and Tapes for High-Field NMR Magnet Qualification.

    Journal of physics. Conference series·2022
    Same author

    Radiant Exitance of Old, New, and Damaged LED Light Curing Units.

    Operative dentistry·2022
    Same author

    Evaluation of a lateral-flow nanoparticle fluorescence assay for TB infection diagnosis.

    The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease·2021
    Same author

    What is the current practice for managing patients with chronic limb-threatening ischaemia in vascular surgery services? A survey of UK vascular surgeons.

    Annals of the Royal College of Surgeons of England·2021
    Same journal

    Contribution of thebesian veins to the physiologic shunt in anesthetized man.

    Journal of applied physiology·2011
    Same journal

    Venous ultrasound catheter-tip technique for evaluation of arterial hemodynamics.

    Journal of applied physiology·1976
    Same journal

    Flow field and mass transport analysis in arteries with longitudinal ridges.

    Journal of applied physiology·1976
    Same journal

    Cardiorespiratory responses of sedentary college women as a function of training intensity.

    Journal of applied physiology·1976
    Same journal

    Genetic influence on normal variability of maximum expiratory flow-volume curves.

    Journal of applied physiology·1976
    Same journal

    Method to optimize high-pressure, multicomponent gas mixing.

    Journal of applied physiology·1976
    See all related articles

    A new in vivo method accurately calibrates ascorbate dilution curves for measuring cardiac output (CO). This technique offers advantages over traditional indicator-based blood flow measurements.

    Area of Science:

    • Physiology
    • Biomedical Engineering

    Background:

    • Accurate measurement of cardiac output (CO) is crucial for assessing cardiovascular function.
    • Traditional indicator dilution methods for CO measurement can be invasive and have limitations.

    Purpose of the Study:

    • To introduce and validate a novel in vivo method for calibrating ascorbate dilution curves.
    • To compare the accuracy of the proposed CO measurement technique against a standard electromagnetic flowmeter.

    Main Methods:

    • Developed an in vivo technique for calibrating ascorbate dilution curves.
    • Measured cardiac output using the proposed method (COi) and an electromagnetic flowmeter (COe).
    • Statistically analyzed the correlation and agreement between the two measurement methods.

    Related Experiment Videos

    Main Results:

    • Cardiac output measurements by the proposed method (COi) averaged 1,284 ml/min.
    • Cardiac output measurements by the electromagnetic flowmeter (COe) averaged 1,281 ml/min.
    • A high correlation (0.92) was observed between COi and COe, with P > 0.90.

    Conclusions:

    • The proposed in vivo method provides accurate cardiac output measurements.
    • This novel technique offers significant advantages over conventional indicator-based blood flow assessments.
    • The validated method shows potential for routine clinical and research applications.