Reference values for differences between cardio-circulatory variables of normal twin fetuses
S E Sonesson1, J C Fouron, L Leduc
1Astrid Lindgren's Children's Hospital, Karolinska Institute, Stockholm, Sweden.
Background:
No reference values exist concerning the differences between cardio-circulatory variables of normal twin fetuses. The normal data could be useful in the identification of conditions causing opposite hemodynamic effects on each twin.
Objective:
To establish the normal differences among cardio-circulatory parameters of twin fetuses during the second and third trimesters of gestation.
Materials And Methods:
Twenty-seven normal twin pregnancies were used in this longitudinal and prospective study. Doppler-echocardiographic investigations were performed every 2-3 weeks starting at an average of 23.11 +/- 3.13 (mean +/- standard deviation) weeks' gestation. At each visit, the following cardio-circulatory variables were evaluated: the cardio-thoracic ratio, the ventricular wall and septal thicknesses, end-diastolic and systolic diameters, ventricular fractional shortenings, velocity of circumferential fibre shortenings and left and right ventricular outputs. In addition the following measurements were made from Doppler recordings: through both aortic and pulmonary valve the acceleration and ejection times, the peak systolic velocities and the velocity time integrals; and through both mitral and tricuspid valves peak velocities of E and A waves and the E/A ratios. Finally the pulsatility index of the umbilical artery was also evaluated.
Results:
There was no single variable where the intertwin difference changed with gestational age. No systematic difference between the smaller and larger twin could be demonstrated for any variables except for the cardio-thoracic ratio.
Conclusion:
Reference tables should permit a comparative approach between the two twins in the investigation of life threatening complications such as twin-to-twin transfusion syndrome.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...