Use of Edman degradation sequence analysis and matrix-assisted laser desorption/ionization mass spectrometry in
J L Lauer-Fields1, H Nagase, G B Fields
1Department of Chemistry and Biochemistry, Florida Atlantic University, Boca Raton 33431-0991, USA.
Abstract:
The matrix metalloproteinase (MMP) family has been implicated in the process of a variety of diseases such as arthritis, atherosclerosis, and tumor cell metastasis. We have been designing single-stranded peptides (SSPs) and triple-helical peptides (THPs) as potential discriminatory MMP substrates. Edman degradation sequence and matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analyses of proteolytic activity have been utilized to aid in further substrate design. THP models of the alpha1(I)772-786 sequence from type I collagen were synthesized to examine the triple-helical substrate specificity of MMP family members. Sequence and MALDI-MS analyses were used in conjunction with a fluorometric assay to determine the exact point of cleavage by each MMP. MMP-1 (interstitial collagenase) cleaved the substrates at a single Gly-Ile bond, analogous to the cleavage site in type I collagen. MMP-2 (Mr 72 000 type IV collagenase; gelatinase A) was found to cleave the substrates at two sites, a Gly-Ile bond and a Gly-Gln bond. MMP-3 (stromelysin 1) was found to cleave only one of the substrates after reaction for 48 h. Ultimately, sequence and MALDI-MS analyses allowed us to detect an additional cleavage site for MMP-2 in comparison to MMP-1, while MMP-3 was found to cleave a substrate after an extended time period. The second cleavage site would cause the kinetic parameters for MMP-2 to be overestimated by the fluorometric assay. Further design variations for these substrates need to consider the presence of more stable triple-helical conformation (to eliminate MMP-3 binding) and the removal of Gly-Gln bonds that may be susceptible to MMP-2.
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Role of Matrix Metalloproteases in Degradation of ECM
A...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...