Scatter/primary in mammography: Monte Carlo validation.

J M Boone1, V N Cooper

  • 1Department of Radiology, University of California, Davis, Sacramento 95817, USA. jmboone@ucdavis.edu

Medical Physics
|September 13, 2000
PubMed
Summary

The SIERRA Monte Carlo simulation accurately calculates the scatter-to-primary ratio (SPR) in mammography. Both direct and convolution methods showed good agreement with published data, validating SIERRA for scatter analysis.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

GEANT4 Monte Carlo simulations for virtual clinical trials in breast X-ray imaging: Proof of concept.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2020
Same author

Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom.

Medical physics·2019
Same author

Evaluation of the BreastSimulator software platform for breast tomography.

Physics in medicine and biology·2017
Same author

Spectrum of bone marrow morphologic findings in hepatitis C patients with and without prior liver transplantation.

International journal of laboratory hematology·2016
Same author

Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129.

Annals of the ICRP·2015
Same author

Simulated lesion, human observer performance comparison between thin-section dedicated breast CT images versus computed thick-section simulated projection images of the breast.

Physics in medicine and biology·2015
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Area of Science:

  • Medical Physics
  • Radiological Imaging
  • Computational Science

Background:

  • Accurate scatter estimation is crucial for mammography image quality.
  • Monte Carlo (MC) simulations are powerful tools for modeling radiation transport.
  • Validating simulation tools like SIERRA is essential for reliable analysis.

Purpose of the Study:

  • To compare and validate the SIERRA Monte Carlo simulation routines for scatter-to-primary ratio (SPR) analysis in mammography.
  • To assess the performance of two distinct MC methods: direct simulation and convolution.

Main Methods:

  • Employed a direct MC simulation method with accurate geometry.
  • Utilized a convolution method with idealized geometry to generate scatter point spread functions (PSFs).

Related Experiment Videos

  • Compared SPR results from both methods against five published literature sources.
  • Main Results:

    • The direct MC method achieved 3.7% accuracy compared to literature.
    • The convolution MC method demonstrated an average accuracy of 7.1%.
    • Comparisons spanned various parameters including field of view, phantom properties, and x-ray energy.

    Conclusions:

    • SIERRA Monte Carlo routines provide accurate SPR calculations for mammography.
    • The validated SIERRA tool is suitable for in-depth studies of scatter phenomena in mammography.
    • Further research can leverage SIERRA for advanced image quality assessments.