Related Experiment Video
Updated: Aug 14, 2026

Direct Intrabronchial Administration to Improve the Selective Agent Deposition Within the Mouse Lung
Published on: May 20, 2019
High-dose intravenous isosorbide-dinitrate is safer and better than Bi-PAP ventilation combined with conventional
A Sharon1, I Shpirer, E Kaluski
1Department of Medicine, Assaf-Harofeh Medical Center, Zerifin, Israel.
Objective:
To determine the feasibility, safety and efficacy of bilevel positive airway ventilation (BiPAP) in the treatment of severe pulmonary edema compared to high dose nitrate therapy.
Background:
Although noninvasive ventilation is increasingly used in the treatment of pulmonary edema, its efficacy has not been compared prospectively with newer treatment modalities.
Methods:
We enrolled 40 consecutive patients with severe pulmonary edema (oxygen saturation <90% on room air prior to treatment). All patients received oxygen at a rate of 10 liter/min, intravenous (IV) furosemide 80 mg and IV morphine 3 mg. Thereafter patients were randomly allocated to receive 1) repeated boluses of IV isosorbide-dinitrate (ISDN) 4 mg every 4 min (n = 20), and 2) BiPAP ventilation and standard dose nitrate therapy (n = 20). Treatment was administered until oxygen saturation increased above 96% or systolic blood pressure decreased to below 110 mm Hg or by more than 30%. Patients whose conditions deteriorated despite therapy were intubated and mechanically ventilated. All treatment was delivered by mobile intensive care units prior to hospital arrival.
Results:
Patients treated by BiPAP had significantly more adverse events. Two BiPAP treated patients died versus zero in the high dose ISDN group. Sixteen BiPAP treated patients (80%) required intubation and mechanical ventilation compared to four (20%) in the high dose ISDN group (p = 0.0004). Myocardial infarction (MI) occurred in 11 (55%) and 2 (10%) patients, respectively (p = 0.006). The combined primary end point (death, mechanical ventilation or MI) was observed in 17 (85%) versus 5 (25%) patients, respectively (p = 0.0003). After 1 h of treatment, oxygen saturation increased to 96 +/- 4% in the high dose ISDN group as compared to 89 +/- 7% in the BiPAP group (p = 0.017). Due to the significant deterioration observed in patients enrolled in the BiPAP arm, the study was prematurely terminated by the safety committee.
Conclusions:
High dose ISDN is safer and better than BiPAP ventilation combined with conventional therapy in patients with severe pulmonary edema.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Heart Failure Drugs: Inotropic Agents
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Acute Coronary Syndrome IV: Interprofessional Care
Cardiopulmonary Resuscitation IV: Pharmacological Management
Heart Failure VI: Adjunct Therapies
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care