Related Experiment Video
Updated: Oct 13, 2026

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
Influence of a poly-ethylene glycol spacer on antigen capture by immobilized antibodies
B C Weimer1, M K Walsh, X Wang
1Department of Nutrition and Food Sciences, Utah State University, Logan, UT 84322, USA. milkbugs@cc.usu.edu
The use of spacers to distance an immobilized antibody from the surface of a support matrix introduces flexibility, which can reduce steric interferences between antibodies leading to a higher antigen capture efficiency. In this paper we investigated the use of a spacer molecule, poly-ethylene glycol (PEG), between the matrix surface and antibodies for the capture of Bacillus globigii, E. coli O157:H7, and ovalbumin. The antigen capture efficiency was determined using a surface ELISA method. Antibodies against the antigens were covalently immobilized either directly or via PEG to glass surfaces using a one-step EDC reaction. The amount of antibody immobilized was determined before blocking the nonspecific binding sites with bovine serum albumin. Antibodies immobilized via a PEG spacer showed a higher capture efficiency compared to direct immobilization, which was more pronounced with large antigens. Antibodies immobilized on glass supports were stable at 65 degrees C for at least 80 min, and the capture efficiency increased with heating at 65 degrees C for 20 min.
The use of spacers to distance an immobilized antibody from the surface of a support matrix introduces flexibility, which can reduce steric interferences between antibodies leading to a higher antigen capture efficiency. In this paper we investigated the use of a spacer molecule, poly-ethylene glycol (PEG), between the matrix surface and antibodies for the capture of Bacillus globigii, E. coli O157:H7, and ovalbumin. The antigen capture efficiency was determined using a surface ELISA method. Antibodies against the antigens were covalently immobilized either directly or via PEG to glass surfaces using a one-step EDC reaction. The amount of antibody immobilized was determined before blocking the nonspecific binding sites with bovine serum albumin. Antibodies immobilized via a PEG spacer showed a higher capture efficiency compared to direct immobilization, which was more pronounced with large antigens. Antibodies immobilized on glass supports were stable at 65 degrees C for at least 80 min, and the capture efficiency increased with heating at 65 degrees C for 20 min.
More Related Videos
08:51Preparation of Poly(pentafluorophenyl acrylate) Functionalized SiO2 Beads for Protein Purification
Published on: November 19, 2018
11:10Antibody Binding Specificity for Kappa (Vκ) Light Chain-containing Human (IgM) Antibodies: Polysialic Acid (PSA) Attached to NCAM as a Case Study
Published on: June 29, 2016
Related Concept Videos
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Immunogold Electron Microscopy