Related Experiment Video
Updated: Jul 25, 2026

Patch Clamp and Perfusion Techniques for Studying Ion Channels Expressed in Xenopus oocytes
Published on: January 10, 2011
Apical nonspecific cation channels in everted collecting tubules of potassium-adapted ambystoma
1Department of Neuroscience and Physiology, State University of New York, Health Science Center, 766 Irving Avenue, Syracuse, New York, 13210, USA.
Abstract:
We observed intermediate conductance channels in approximately 20% of successful patch-clamp seals made on collecting tubules dissected from Ambystoma adapted to 50 mm potassium. These channels were rarely observed in collecting tubules taken from animals which were maintained in tap water. Potassium-adaptation either leads to an increase in the number of channels present or activates quiescent channels. In cell-attached patches the conductance averaged 30.3 +/- 2.4 (9) pS. Since replacement of the chloride in the patch pipette with gluconate did not change the conductance, the channel carries cations, not anions. Notably, channel activity was observed at both positive and negative pipette voltages. When the pipette was voltage clamped at 0 mV or positive voltages, the current was directed inward, consistent with the movement of sodium into the cell. The pipette voltage at which the polarity of the current reversed (movement of potassium into the pipette) was -29.6 +/- 6.5(9) mV. Open probability at 0 mV pipette voltage was 0.08 +/- 0.03 and was unaffected when the apical membrane was exposed to either 2 x 10(-6) or 2 x 10(-5) m of amiloride. Exposure of the basolateral surface of the tubule to a saline containing 15 mm potassium caused a significant increase (P less than 0.001) in the open probability of these channels to 0.139 +/- 0.002 without affecting the conductance of the apical channel. These data illustrate the presence of an intermediate conductance, poorly selective, amiloride-insensitive cation channel in native vertebrate collecting tubule. We postulate that, at least in amphibia, this channel may be used to secrete potassium.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Renal Tubule and Collecting Duct
Proximal Convoluted Tubule (PCT):
The PCT is the initial segment of the renal tubule, extending from the Bowman's capsule that encloses the glomerulus. Its convoluted structure and microvilli-lined cells increase the surface area for reabsorption. The PCT reabsorbs glucose, amino acids, sodium, and water from the filtrate, ensuring essential...
Reabsorption and Secretion in the Loop of Henle
Reabsorption and Secretion in the DCT and Collecting Duct
The distal part of the DCT, along with the...
Physiology of the Genitourinary System II: Tubular Reabsorption and Secretion

