Skin absorption of some vaporous solvents in volunteers

S Kezic1, A C Monster, J Krüse

  • 1Coronel Institute, Laboratory of Human Toxicology, Academic Medical Center, University of Amsterdam, The Netherlands. s.kezic@amc.uva.nl

Abstract

Related Concept Videos

Vapor Pressure Lowering03:28

Vapor Pressure Lowering

The equilibrium vapor pressure of a liquid is the pressure exerted by its gaseous phase when vaporization and condensation are occurring at equal rates: Dissolving a nonvolatile substance in volatile liquid results in a lowering of the liquid’s vapor pressure. This phenomenon can be explained by considering the effect of added solute molecules on the liquid's vaporization and condensation processes. To vaporize, solvent molecules must be present at the surface of the solution. The presence of...
Ideal Solutions02:24

Ideal Solutions

According to Raoult’s law, the partial vapor pressure of a solvent in a solution is equal or identical to the vapor pressure of the pure solvent multiplied by its mole fraction in the solution. However, Raoult's Law is only valid for ideal solutions. For a solution to be ideal, the solvent-solute interaction must be just as strong as a solvent-solvent or solute-solute interaction. This suggests that both the solute and the solvent would use the same amount of energy to escape to the vapor phase...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Non-Oral Extravascular Drug Absorption Routes01:15

Non-Oral Extravascular Drug Absorption Routes

Non-oral extravascular routes, which encompass sublingual, buccal, topical, intramuscular, and inhalation methods, primarily utilize passive diffusion to transport drugs into the systemic circulation. The absorption rates and effectiveness of these routes depend on the drug's physicochemical properties, as well as the patient's anatomical and pathophysiological state.
Lipophilic drugs that are stable at salivary pH (6) and exhibit minimal binding to the oral mucosa are absorbed more effectively...