Related Experiment Video
Updated: Aug 11, 2026

Characteristics of Precipitation-formed Polyethylene Glycol Microgels Are Controlled by Molecular Weight of Reactants
Published on: December 23, 2013
Multidimensional analysis of poly(ethylene glycols) by size exclusion chromatography and dynamic surface tension
1Center for Process Analytical Chemistry, Department of Chemistry, University of Washington, Seattle 98195, USA.
Abstract:
Substantial improvements in a multidimensional dynamic surface tension detector (DSTD) are presented. Rapid, online calibration and measurement of the dynamic surface tension for high-performance liquid chromatography separations is achieved. Dynamic surface tension is determined by measuring the differential pressure across the liquid-air interface of repeatedly growing and detaching drops. Continuous surface tension measurement throughout the entire drop growth (50 ms to 2 s) is achieved, for each eluting drop, providing insight into the kinetic behavior of molecular orientation processes at the liquid-air interface. Three-dimensional data are obtained, with surface tension first converted to surface pressure, which is plotted as a function of elution time axis versus drop time axis. Two key innovations will be reported. First, a novel calibration procedure is described and implemented. Differential pressure signals from three drops (mobile phase, standard in mobile phase, and analyte in mobile phase) are utilized to make the dynamic surface tension measurement, thereby eliminating the need for optical imaging, and viscosity and hydrostatic pressure corrections, as required by other methods. Only pressure signals from one mobile-phase drop and one standard drop pressure signal are required, while the analyte drop pressure signal is measured along the chromatographic time axis. Second, corrections for drop elongation are not required, because the drops are precisely detached by an air burst actuation method in a regime were the surface tension forces significantly dominate gravitational forces. Drops that would fall with a volume of approximately 10 microL due to gravity are precisely and repeatedly detached earlier at a volume of 2 microL. The sensitivity and unique selectivity of the DSTD opens up new possibilities in the analysis of small molecular weight polymers of varying degrees of surface activity, as illustrated for the size-exclusion chromatography analyses of complex poly(ethylene glycol) (PEG) samples. Using partial least squares for data analysis, polydispersity of complex PEG samples is determined at a relative precision of approximately 1%.
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Analyte Adsorption and Distribution
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...