A two-step algorithm for predicting portal dose images in arbitrary detectors.

B M McCurdy1, S Pistorius

  • 1Medical Physics Department, Winnipeg, Canada.

Medical Physics
|September 30, 2000
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Erratum: "Real time breast microwave radar image reconstruction using circular holography: A study of experimental feasibility" [Med. Phys. 38, 5420-5431 (2011)].

Medical physics·2017
Same author

Poster - Thur Eve - 14: The effect of fluence and detector size on image quality in multi-projection compton scatter tomography.

Medical physics·2017
Same author

Poster - Thurs Eve-33: Initial implementation of a novel, measurement-based IMRT QA method.

Medical physics·2017
Same author

Sci-Sat AM(1): Imaging-05: Analytical scatter estimation for cone-beam computed tomography.

Medical physics·2017
Same author

[Complex pelvic and sarcoma surgery with vascular replacement].

Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen·2015
Same author

[German S3-guideline "Diagnosis and treatment of esophagogastric cancer"].

Zeitschrift fur Gastroenterologie·2011
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

This study presents a fast and accurate two-step model for predicting portal dose in radiation therapy verification. The advanced algorithm achieves better than 3% agreement, improving patient safety through precise dosimetric verification.

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Image-Guided Therapy

Background:

  • Portal imaging systems are increasingly used for dosimetric verification in radiation therapy.
  • Quantitative comparison of measured and predicted images is crucial for treatment accuracy.
  • Existing methods require advancement for precise dose deposition prediction in detectors.

Purpose of the Study:

  • To develop and validate a two-step model for predicting dose deposition in arbitrary portal imaging detectors.
  • To enhance the accuracy of dosimetric verification in radiation therapy.
  • To provide a fast and reliable tool for predicting portal dose.

Main Methods:

  • A two-step algorithm utilizing patient CT data, source-detector distance, and incident beam fluence.

Related Experiment Videos

  • Step 1: Ray-tracing for primary fluence and Monte Carlo scatter kernels for scatter fluence prediction.
  • Step 2: Superposition of Monte Carlo pencil beam kernels with predicted fluence for dose deposition, modeling spectral softening.
  • Main Results:

    • The algorithm accurately predicts dose deposition in various phantoms (slab, lung, anthropomorphic) and configurations (6 MV, 23 MV, 10-80 cm air gaps).
    • Agreement between predicted and measured portal dose exceeds 3% in low dose gradient regions (<30%/cm).
    • The model effectively separates primary and scatter dose contributions and accommodates diverse detector types.

    Conclusions:

    • The developed portal dose prediction algorithm is fast, accurate, and versatile.
    • It enables precise dosimetric verification by modeling arbitrary detectors and accounting for primary and scatter radiation.
    • This advancement supports improved image-guided radiation therapy and patient safety.