Performance evaluation of a new chemiluminescent cardiac troponin I assay
A Dasgupta1, L Chow, L Nazareno
1Department of Pathology and Laboratory Medicine, University of Texas-Houston Medical School, Houston, Texas 77030, USA.
Abstract:
Cardiac troponin I is a marker for diagnosis of myocardial damage. Several immunoassays are currently available for determination of concentrations of troponin I in serum. We evaluated a chemiluminescent assay for troponin I using ACS:180 automated analyzer (Bayer Diagnostics). We compared our results with two other immunoassays using the OPUS Magnum (OPUS troponin I assay, Dade Behring) and AxSYM (microparticle enzyme immunoassay, Abbott) analyzers. The within-run and between-run CVs were less than 5% for all three levels of controls. The chemiluminescent assay for troponin I was linear up to a serum troponin I concentration of 50 ng/mL and the detection limit was 0.1 ng/mL of troponin. A good correlation between troponin I concentration measured by the chemiluminescent assay (y axis) and the microparticle enzyme immunoassay (MEIA) (x axis) was observed, although the concentrations of troponin I in individual specimens were approximately four times higher, when measured by the MEIA assay, than those measured by chemiluminescent assay. The correlation coefficient was 0.98 with the regression equation y = 0.22x + 1.125. We also observed a good correlation in troponin I concentrations obtained by the chemiluminescent assay (y axis) and OPUS troponin I assay (x axis). The correlation coefficient was 0.96 and the regression equation was y = 0.79x - 0.52. The correlation coefficient was 0.93 when we compared troponin I concentrations obtained by the OPUS assay (x axis) with the corresponding concentrations obtained by the MEIA assay (y axis). The corresponding regression equation was y = 0.25x + 3.5. We conclude that the chemiluminescent troponin I assay showed good analytical performance.
More Related Videos
09:23Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...