Electrocardiographic ST-segment changes during acute, severe isovolemic hemodilution in humans
J M Leung1, R B Weiskopf, J Feiner
1Department of Anesthesia, University of California, San Francisco, USA.jmleung@itsa.ucsf.edu
Background:
Controversy exists regarding the lowest blood hemoglobin concentration that can be safely tolerated. The authors studied healthy resting humans to test the hypothesis that acute isovolemic reduction of blood hemoglobin concentration to 5 g/dl would produce an imbalance in myocardial oxygen supply and demand, resulting in myocardial ischemia.
Methods:
Fifty-five conscious healthy human volunteers were studied. Isovolemic removal of aliquots of blood reduced blood hemoglobin concentration from 12.8 +/- 1.2 to 5.2 +/- 0.5 g/dl (mean +/- SD). Removed blood was replaced simultaneously with intravenous fluids to maintain constant isovolemia. Hemodynamics and arterial oxygen content (Cao2) were measured before and after removal of each aliquot of blood. Electrocardiographic (ECG) changes were monitored continuously using a Holter ECG recorder for detection of myocardial ischemia.
Results:
During hemodilution, transient, reversible ST-segment depression developed in three subjects as seen on the electrocardiogram during hemodilution. These changes occurred at hemoglobin concentrations of 5-7 g/dl while the subjects were asymptomatic. Two of three subjects with ECG changes had significantly higher heart rates than those without ECG changes at the same hemoglobin concentrations. When evaluating the entire study period, the subjects who had ECG ST-segment changes had significantly higher maximum heart rates than those without ECG changes, despite having similar baseline values.
Conclusion:
With acute reduction of hemoglobin concentration to 5 g/dl, ECG ST-segment changes developed in 3 of 55 healthy conscious adults and were suggestive of, but not conclusive for, myocardial ischemia. The higher heart rates that developed during hemodilution may have contributed to the development of an imbalance between myocardial supply and demand resulting in ECG evidence of myocardial ischemia. However, these ECG changes appear to be benign because they were reversible and not accompanied by symptoms.
More Related Videos
09:23Confirmation of Myocardial Ischemia and Reperfusion Injury in Mice Using Surface Pad Electrocardiography
Published on: November 24, 2016
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...