Related Experiment Video
Updated: Oct 11, 2026

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
A study of the effectiveness of different measuring times and counting methods of human radial pulse rates
1University of Ulster, Northern Ireland. t55294@hotmail.com
Abstract:
The purpose of this study was to determine the reliability and validity of measuring resting radial pulse rates by the use of three measuring times: 15, 30 and 60 s; and two counting methods: one beginning with zero (0) and the other with one (1). A two-factor within-subjects experimental design was used to determine the mean difference between pulse rates obtained from the radial artery, and the heart rates recorded by simultaneous electrocardiographic (ECG) recordings. The sample comprised 206 students. Mean difference was used to calculate the extent of any differences between radial pulse rates and the rate shown by the ECG. The interaction between measuring time and counting methods was confirmed using a two-factor within-subjects analysis of variance. For all types of measuring time, the counting from zero method produced a greater mean difference than the counting from one method. For all measuring times, the mean difference between radial pulse rates and rates shown by the ECG were non-significant in the counting from one method. In other words, when the pulse rate is counted from one, the rates obtained at 15 or 30 s could be used to predict the one-minute resting pulse rates. The results of this study can contribute to the evidence base for this commonly used aspect of patient care.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...