Field-emission scanning electron microscopy of the internal cellular organization of fungi

W H Müller1, A C van Aelst, B M Humbel

  • 1Department of Molecular Cell Biology, EMSA, Utrecht University, The Netherlands. W.H.Muller@bio.uu.nl

Scanning
|October 7, 2000
PubMed

Insights

Scanning electron microscopy (SEM) offers a new way to view fungal cell structures. This method reveals detailed intracellular ultrastructure, including organelles and septal pore caps, in fungi.

Area of Science:

  • Mycology
  • Cell Biology
  • Microscopy

Background:

  • Transmission electron microscopy (TEM) of sectioned fungal material is a standard method for studying hyphal cellular organization.
  • Observing intact fungal cells offers an alternative perspective to sectioned material.

Purpose of the Study:

  • To develop and validate a scanning electron microscopy (SEM) method for visualizing the intracellular ultrastructure of fungal hyphae.
  • To provide a detailed internal view of fungal cellular organization as an alternative to traditional TEM methods.

Main Methods:

  • Fungal colonies were chemically fixed (glutaraldehyde, osmium tetroxide) and treated with dimethyl sulfoxide.
  • Samples underwent freeze-fracturing, maceration in osmium tetroxide to remove the cytoplasmic matrix, and freeze-substitution dehydration.
  • Final processing included critical point drying, mounting, sputter coating, and imaging with field-emission SEM.

Main Results:

  • The SEM method successfully produced clear images of intracellular fungal structures.
  • Visualized organelles included mitochondria (elongated and spherical), the nucleus, and intravacuolar structures.
  • Detailed views of tubular and plate-like endoplasmic reticulum and various septal pore caps were obtained.

Conclusions:

  • This SEM procedure is a powerful approach for studying the intracellular ultrastructure of fungi.
  • It provides high-resolution imaging of organelles and cellular components within intact hyphae.
  • This technique offers a valuable alternative for fungal cell biology research.

Related Concept Videos

Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...