High-temperature X-ray diffraction measurement of sanidine thermal expansion
J R Mackert1, S W Twiggs, A L Williams
1Department of Oral Rehabilitation, School of Dentistry, Medical College of Georgia, Augusta 30912-1260, USA. rmackert@mail.mcg.edu
Abstract:
Dental porcelains that are designed to be fused to PFM (porcelain-fused-to-metal) alloys are formulated by their manufacturers to be closely matched in thermal expansion to these alloys. The high thermal expansion of the mineral leucite has been exploited to regulate porcelain expansion. Leucite, however, has been observed to convert to the sanidine polymorph of feldspar during certain heat treatments within the normal firing range of dental porcelain. The effects of this conversion on porcelain thermal expansion and porcelain-metal thermal compatibility have been uncertain, due to the paucity of published data on the thermal expansion of sanidine. The purpose of this study was to measure the thermal expansion of sanidine by high-temperature X-ray diffraction over the temperature range in which thermal mismatch stresses can develop in porcelain-fused-to-metal restorations, i.e., from room temperature to 700 degrees C. The lattice parameters a, b, c, and beta were determined from the d-spacings and hkl values of multiple reflections by means of a least-squares iteration. The dependence of each lattice parameter on temperature was determined via analysis of variance, and the coefficient of thermal expansion, alpha, was obtained from this analysis. The lattice parameters of sanidine at room temperature were determined to be: a = 0.8524 +/- 0.0015 nm, b = 1.3020 +/- 0.0004 nm, c = 0.7165 +/- 0.0002 nm, and beta = 116.02 degrees +/- 0.01 degree (mean +/- 95% confidence interval). The linear thermal expansion coefficient, a, over the range from room temperature to 700 degrees C was determined to be 4.1 x 10(-6) K(-1) +/- 0.6 x 10(6) K(-1) (mean +/- 95% confidence interval). Because the coefficient of thermal expansion for sanidine is substantially lower than that of leucite (the effective linear thermal coefficient of thermal expansion of leucite over the range of 25 degrees to 700 degrees C is 28 x 10(-6) K(-1)), the conversion of leucite to sanidine during porcelain heat treatments would produce a detrimental lowering of the porcelain thermal expansion.
More Related Videos
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.