Microbiologic contamination study of nebulizers after aerosol therapy in patients with cystic fibrosis
Related Experiment Video
Updated: Sep 21, 2026

The WinCF Model - An Inexpensive and Tractable Microcosm of a Mucus Plugged Bronchiole to Study the Microbiology of Lung Infections
Published on: May 8, 2017
Insights
Nebulizers used by cystic fibrosis patients with Pseudomonas aeruginosa infections are often contaminated. Regular cleaning is crucial to prevent the spread of pathogenic bacteria and maintain treatment efficacy.
Area of Science:
- Medical Microbiology
- Pulmonology
- Infectious Diseases
Background:
- Cystic fibrosis (CF) patients with chronic Pseudomonas aeruginosa infections often use aerosol therapy.
- Delivery systems, such as nebulizers, may become contaminated after use.
Purpose of the Study:
- To assess the level of contamination in nebulizer devices after aerosol therapy in CF patients with P. aeruginosa infections.
Main Methods:
- Fifty-three CF patients (age ≥7 years) with P. aeruginosa infection, treated with recombinant deoxyribonuclease, and able to produce sputum were enrolled.
- Nebulizer devices were collected and analyzed for bacterial contamination.
Main Results:
- Out of 53 patients, 44 nebulizers were analyzed after excluding 9 devices.
- 37 nebulizers showed P. aeruginosa colonization (≥10^6 CFU/mL), and 7 showed counts between 10^5 and 10^6 CFU/mL.
Conclusions:
- Nebulizers used by P. aeruginosa-infected CF patients are frequently contaminated with pathogenic flora.
- This highlights the importance of proper cleaning protocols for nebulizer devices to prevent secondary infections.
Background:
To evaluate the contamination of delivery systems after an aerosol therapy session in patients with cystic fibrosis who have chronic Pseudomonas aeruginosa infection.
Methods:
Fifty-three patients with cystic fibrosis were enrolled in the study from March 1996 to June 1997. All patients were age 7 years or older and had P aeruginosa infection. They also had been treated with recombinant deoxyribonuclease and were capable of producing sputum for culture.
Results:
Nine devices were excluded for the study. A total of 44 nebulizers were included: 37 from patients with P aeruginosa colonization with a count of 10(6) colony-forming units/mL or more and 7 with a count of between 10(5) colony-forming units/mL and 10(6) colony-forming units/mL.
Conclusion:
This study demonstrates that in the absence of cleaning, nebulizers of patients with cystic fibrosis who are infected with P aeruginosa are likely to be contaminated by a pathogenic flora.
Related Concept Videos
Cystic Fibrosis: Pathogenesis
CF is primarily caused by a genetic mutation in a chromosome 7 gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The most common gene mutation leading to CF is the ΔF508 mutation, but...
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Microbiota of the Respiratory Tract