Inadvertent transpericardial insertion of a central venous line with cardiac tamponade failure of preventive
H Losert1, R Prokesch, M Grabenwöger
1Department of Internal Medicine I, Medical School, University of Vienna, Austria. heidrun.losert@akh-wien.ac.at
Insights
Central venous catheter malposition after cardiac surgery can lead to cardiac tamponade, a life-threatening complication. Vigilance and awareness of potential safety practice pitfalls are crucial for preventing such hazards.
Area of Science:
- Cardiology
- Anesthesiology
- Intensive Care Medicine
Background:
- Central venous catheter (CVC) placement is a common procedure in perioperative and intensive care settings.
- Complications associated with CVCs can range from thrombosis to life-threatening events like cardiac tamponade.
- Ensuring correct catheter tip placement is paramount for patient safety.
Observation:
- A 56-year-old male, post-cardiac surgery, developed cardiac tamponade after contrast medium administration via a CVC.
- Pericardiotomy revealed the CVC traversing the pericardial sac before re-entering the superior vena cava.
- The catheter position was not detected by standard safety checks like chest radiography, free venous blood return, or manometry.
Findings:
- Standard preventive practices for CVC placement may not always detect malposition, particularly in unusual anatomical presentations.
- The case highlights a rare but potentially fatal complication of CVC malposition.
- An unusual high reflection was noted near the catheter's path through the pericardial sac.
Implications:
- Anesthesiologists and intensivists must be aware of the limitations of routine safety measures for CVC placement.
- Continuous vigilance and recognition of potential pitfalls are essential to prevent severe adverse events.
- This case underscores the need for a high index of suspicion for malposition in patients developing unexpected complications.
Abstract:
A 56-year-old man who had undergone cardiac surgery suffered from cardiac tamponade after administration of contrast-medium through a central venous catheter. Pericardiotomy showed the catheter transversing the pericardial sac just beneath an unusual high reflection and then reentering the superior vena cava. Preventive practices including chest radiography, confirming free venous blood return and manometry may fail to detect catheter malposition in rare cases. Knowledge of potential pitfalls in using generally recommended safety practices and continuous vigilance are essential for the anesthesiologist and intensivist in avoiding potentially lethal hazards.