Related Experiment Video
Updated: Jul 28, 2026

Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
Dynamic contrast-enhanced MR angiography from the distal aorta to the ankle joint with a step-by-step technique
1Department of Clinical Radiology, Klinikum der LMU, Grobetahadern, Marchioninistr. 15, 81377 München, Germany.
Objective:
The aim of this study was to visualize the arteries from the distal aorta to the ankle joint and to determine the accuracy of MR angiography for detecting stenoses and occlusions.
Subjects And Methods:
Twenty-four patients with peripheral arterial occlusive disease underwent digital subtraction angiography and were examined on a 1.5-T MR scanner. The transit time for contrast material was determined with a test bolus injection. A T1-weighted three-dimensional gradient-echo sequence with short TR and TE was used for a dynamic measurement at the level of the iliac arteries, the upper leg, and the lower leg arteries. For each level a single dose of gadolinium was injected into an antecubital vein with an MR power injector. Maximal-intensity-projection reconstructions were calculated after subtraction of the first measurement at each level. Two experienced MR radiologists who were unaware of the digital subtraction angiography results interactively evaluated both the MIP reconstructions and the single slices on a workstation, first independently and then in a consensus interpretation.
Results:
With digital subtraction angiography, 80 hemodynamically significant stenoses and 39 occlusions were detected. For the stenoses and occlusions, a sensitivity of 100% was found for MR angiography. The specificity for the assessment of stenoses and occlusions was 98% and 94%, respectively, for the iliac arteries; 98% and 94%, respectively, for the upper leg arteries; and 94% and 95%, respectively, for the lower leg arteries. Most false-positive findings of occlusion were due to metal stents present in the iliac (n = 3) and upper leg (n = 4) arteries.
Conclusion:
The MR imaging technique that we used revealed the arteries from the distal aorta to the ankle and proved to be reliable at showing arterial stenoses and occlusions.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:35Sample Preparation for Computed Tomography-based Three-dimensional Visualization of Murine Hind-limb Vessels
Published on: October 7, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies VII: Vascular Imaging