Adaptation of the Fresenius PD+ Cycler for a hearing-impaired patient
1Dialysis Clinic, Inc., Medical College of Pennsylvania, Philadelphia, USA.
Abstract:
Continuous cycling peritoneal dialysis (CCPD) uses a cycler to perform dialysis exchanges and requires the patient to respond to an audible alarm signifying an interruption in the therapy. Consequently, an unassisted hearing-impaired patient could not use the system. By converting the standard alarm to a vibrating signal, the cycler was successfully adapted to accommodate the special needs of our hearing-impaired patient. The items required for the modification were the Sonic Alert Wake Up Alarm (Model SA-WA300: Sonic Alert, Troy, MI, U.S.A.) and the Sonic Alert Super Shaker Bed Vibrator (Model SA-SS120V: Sonic Alert). The patient can place the vibrator under either the pillow or the mattress. When the cycler alarm is activated, vibration wakens the patient. The equipment was purchased from Harris Communications (Eden Prairie, MN, U.S.A.) through a referral by the Easter Seal Society. Three days were needed to complete training compared to an average of one or two days for patients previously trained for continuous ambulatory peritoneal dialysis (CAPD). The patient remained on cycler therapy for approximately four months when the unrelated development of an abdominal hernia required termination of peritoneal dialysis and subsequent transfer to hemodialysis. In conclusion, a modified cycler can provide a safe and efficient renal replacement therapy option for a hearing-impaired patient.
More Related Videos
06:04Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
03:49Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode
Published on: October 11, 2024
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peritoneal Dialysis I: Introduction and Procedure