Control of transient chaos in tent maps near crisis. I. Fixed point targeting

Place1, Arrowsmith

  • 1Mathematics Research Centre, Queen Mary and Westfield College, University of London, London E1 4NS, United Kingdom.

Related Concept Videos

Microtubule Instability02:17

Microtubule Instability

Microtubules are hollow cylindrical filaments having a diameter of approximately 25 nm and a length that varies from 200 nm to 25 μm. GTP-bound tubulin subunits form αβ-heterodimers for microtubule assembly. These core building blocks interact longitudinally, polymerizing into protofilaments. The protofilaments then interact with one another through lateral bonding forces to form stable cylindrical microtubules. These cylindrical filaments are dynamic as they undergo repeated assembly and...
Microtubule Instability02:17

Microtubule Instability

Microtubules are hollow cylindrical filaments having a diameter of approximately 25 nm and a length that varies from 200 nm to 25 μm. GTP-bound tubulin subunits form αβ-heterodimers for microtubule assembly. These core building blocks interact longitudinally, polymerizing into protofilaments. The protofilaments then interact with one another through lateral bonding forces to form stable cylindrical microtubules. These cylindrical filaments are dynamic as they undergo repeated assembly and...
Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's response.
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
Control System Problem01:21

Control System Problem

In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is observed...