Related Experiment Video
Updated: Aug 15, 2026

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry
Published on: July 12, 2013
Capillary electrophoresis--matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using a
1Barnett Institute and Department of Chemistry, Northeastern University, Boston, Massachusetts 02115, USA.
Abstract:
An improved vacuum deposition interface for coupling capillary electrophoresis with MALDI-TOF MS has been developed. Liquid samples consisting of analyte and matrix were deposited on a moving tape in the evacuated source chamber of a TOF mass spectrometer, enabling 24 h of uninterrupted analysis. The vacuum deposition procedure was compared with the dried-droplet method, and it was found that vacuum deposition generated significantly more reproducible signal intensity, eliminating the need for "sweet spot" searching. A concentration detection limit in the low-nanomolar range has been achieved with a low-attomole amount of sample consumed per spectrum. In addition, ion suppression caused by hydrophobicity differences in the analytes was reduced. To minimize ion suppression further, separation prior to MALDI MS analysis was employed. The performance of capillary electrophoresis (CE)-MALDI-TOF MS using the vacuum deposition interface was evaluated with a peptide mixture injected at low-femtomole levels. All peptides were baseline resolved with separation efficiencies in the range of 250000-400000 plates/m (2-3-s band half-width), demonstrating the high separation efficiency of the CE-MALDI MS coupling. A fast (approximately 40 s) CE separation of a mixture of angiotensins was found to reduce significantly ion suppression and enable trace level detection. It was also shown, for the analysis of an enolase digest, that sequence coverage of 65% was obtained using CE separation compared to 52% using step-elution solid-phase extraction and 44% in the control experiment using an unseparated mixture.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
07:55Preparation of Hard Palm Seeds for Matrix-Assisted Laser Desorption/Ionization-Imaging Mass Spectrometry Analysis
Published on: June 30, 2023
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
MALDI-TOF Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Matrix-Assisted Laser Desorption Ionization (MALDI)