Venous oxygen measurements in the inferior vena cava in neonates with respiratory failure
1Department of Pediatrics, Division of Neonatology, Sophia Hospital, Zwolle, The Netherlands.
Abstract:
BACKGROUND: The present study was undertaken to examine the feasibility of venous oxygen measurements in the inferior vena cava (IVC) via a catheter through the umbilical vein. This may serve as a proxy for mixed venous oxygenation and the complications of right atrial cannulation can be avoided at the same time. It has the added advantage of not being affected by atrial right-left shunting. RESULTS: The study included 22 neonates requiring mechanical ventilation for respiratory insufficiency. The success rate of catheterization of the IVC via the umbilical vein was 81% and there was no catheter-related complications. Fifty paired blood samples were obtained and analyzed while the patients were hemodynamically stable. Linear regression analysis showed a poor correlation between arterial oxygen tension (PaO2) and the arterial-venous oxygen content difference [C(a-v)O2], r = -0.005, and between PaO2 and the fractional oxygen extraction (FOE), r = -0.114. There was also a poor correlation between arterial oxygen saturation (SaO2) and C(a-v)O2, r = -0.057, and between SaO2 and FOE, r =-0.139. The correlations between venous oxygen tension (PvO2) and C(a-v)O2 and between PvO2 and FOE were r = -0.528 and r = 0.592, respectively. There were good correlations between various oxygen saturation (SvO2) and C(a-v)O2, r = -0.634, and between SvO2 FOE, r = -0.712. CONCLUSION: Venous oxygen measurement in the IVC via an umbilical vein catheter is a simple and safe procedure and provides information about the tissue oxygenation status of critically ill neonates.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...