Use of an age-adjusted Doppler E/A ratio in patients with moderate to severe hypertension
Related Experiment Video
Updated: Oct 10, 2026

Pulsed Wave Doppler Assessment of Diastolic Dysfunction in the ZSF-1 Rat Model of Pulmonary Hypertension Due to Left Heart Disease
Published on: May 22, 2026
H Herkner1, M Müllner, H Domanovits
1Department of Emergency Medicine, Vienna General Hospital--University Clinics, Austria.
Objective:
To assess the ratio of early (E) to late atrial (A) mitral Doppler peak flow velocity (Doppler E/A ratio) before and after adjustment for age in patients with moderate to severe hypertension, in whom left ventricular diastolic dysfunction is an early finding. Mitral flow patterns can be used to assess diastolic filling characteristics, and the Doppler E/A ratio is the parameter most commonly used, although it is known to be strongly age dependent. There are no established normal values for this ratio.
Design:
Retrospective data analysis.
Setting:
A 2000-bed tertiary-care teaching hospital.
Patients:
We studied 190 patients (99 women and 91 men; ages 55 +/- 13 years) with moderate to severe hypertension.
Interventions:
The ratio of early (E) to late atrial (A) mitral Doppler peak flow velocity was measured. As this ratio depends on age, a Z score was calculated to control for this influence. The Z score is the standardized normal deviation of the mean, with a normal value of 0 +/- 2.
Main Outcome Measures:
Sensitivities and specificities for detecting an age-dependent reduction in Doppler E/A score (Z score less than -2) with a non-age-dependent Doppler E/A ratio (less than 1) were calculated.
Results:
In 106 of the patients (56%) the Doppler E/A ratio was less than 1.0. Only nine patients (4.7%) had a Z score less than -2. The sensitivity of the Doppler E/A ratio threshold of 1.0 for detecting a Z score less than -2 was 0.89 and the specificity was 0.46. A Z score less than -2 was found only in patients younger than 45 years.
Conclusions:
The Doppler E/A ratio was reduced in a large proportion of our patients. However, after correction for age it was decreased in only 4.7% of these patients. The use of a single Doppler E/A ratio threshold value has a weak diagnostic power to detect age-independent changes in mitral flow patterns.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration