D S Greenes1, G R Fleisher, I Kohane
1Division of Emergency Medicine, Children's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA. greenes@a1.tch.harvard.edu
Background:
Results of some laboratory tests for Emergency Department (ED) patients return hours to days after the patient is discharged. Inadequate follow-up for these late-arriving results poses medical and legal risks. We have developed, but not yet implemented, a computerized system called the Automated Late-Arriving Results Monitoring System (ALARMS). ALARMS scans the hospital's laboratory and ED registration databases to generate an electronic daily log of all late-arriving abnormal laboratory results for ED patients.
Objective:
To determine the potential impact of ALARMS by assessing our ED's current quality of documented follow-up of late-arriving laboratory results.
Methods:
We applied ALARMS retrospectively, to find all abnormal late-arriving laboratory results returned between 5/1/96 and 4/30/98 for ED patients for the following three tests: serum lead levels, Chlamydia cultures, or urine pregnancy tests. Medical records were reviewed for documentation of follow-up, which was considered appropriate if a clinician noted the abnormal result and documented a follow-up plan within 1 week after the result became available. Medical records were also reviewed for any evidence of complications attributable to delayed or inadequate follow-up.
Results:
Over the 2-year study period, no appropriate follow-up was documented in 6/18 (33%) cases of elevated lead levels, 3/4 (75%) cases of late-arriving positive pregnancy tests, and 23/39 (59%) cases of positive Chlamydia cultures. One case of a positive Chlamydia culture, for which there was no documented follow-up, was associated with subsequent development of pelvic inflammatory disease.
Conclusion:
Our current system of documented follow-up for late-arriving laboratory results has deficiencies. ALARMS, a computerized system of alerts for emergency physicians, has the potential to substantially improve documented follow-up of late-arriving laboratory results in the ED.
Related Concept Videos
Automated Microbial Diagnostics
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Methods of Documentation VII: EMR
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters assessment...
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test