Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted

U G Nolte1, J Finsterbusch, J Frahm

  • 1Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany.

Magnetic Resonance in Medicine
|November 7, 2000
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Bilateral in vivo assessment of mandibular chewing dynamics using multi-slice real-time MRI: the rotation-translation-ratio in normal and displaced TMJ discs.

Clinical oral investigations·2025
Same author

Blood and liver telomere length, mitochondrial DNA copy number, and hepatic gene expression of mitochondrial dynamics in mid-lactation cows supplemented with l-carnitine under systemic inflammation.

Journal of dairy science·2023
Same author

Decoding cerebro-spinal signatures of human behavior: Application to motor sequence learning.

NeuroImage·2023
Same author

Effects of dietary l-carnitine supplementation on the response to an inflammatory challenge in mid-lactating dairy cows: Hepatic mRNA abundance of genes involved in fatty acid metabolism.

Journal of dairy science·2021
Same author

Comparison of performance and metabolism from late pregnancy to early lactation in dairy cows with elevated v. normal body condition at dry-off.

Animal : an international journal of animal bioscience·2019
Same author

Interrelations between the rumen microbiota and production, behavioral, rumen fermentation, metabolic, and immunological attributes of dairy cows.

Journal of dairy science·2018

A new subsecond magnetic resonance imaging (MRI) technique using diffusion-weighted (DW) spin-echo and stimulated echo acquisition mode (STEAM) provides isotropic diffusion mapping. This method avoids artifacts common in echo-planar imaging (EPI), offering clearer brain imaging.

Area of Science:

  • Magnetic Resonance Imaging
  • Diffusion Tensor Imaging
  • Neuroimaging

Background:

  • Echo-planar imaging (EPI) is widely used for diffusion mapping but is susceptible to artifacts from magnetic field variations.
  • Tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts can cause signal loss and geometric distortions in EPI.
  • A need exists for faster, more robust diffusion MRI techniques for accurate brain imaging.

Purpose of the Study:

  • To describe a novel subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping.
  • To evaluate the performance of this technique compared to echo-planar imaging (EPI).
  • To demonstrate the capability for high-resolution brain imaging with reduced artifacts.

Main Methods:

  • A subsecond MRI technique combining diffusion-weighted (DW) spin-echo preparation and stimulated echo acquisition mode (STEAM) was developed.

Related Experiment Videos

  • Diffusion encoding involved scans with and without DW gradients at b-values of 490 and 1000 sec/mm².
  • Automated on-line evaluation generated isotropic DW images and ADC maps.
  • Main Results:

    • The DW single-shot STEAM MRI technique achieved single-shot images within 559 msec.
    • Brain imaging of healthy subjects was completed in 78 seconds for 20 contiguous sections at 2.0 x 2.0 mm² resolution.
    • High-resolution (1.0 x 1.0 mm²) studies were obtained within 5 min 13 sec with four averages.
    • While exhibiting lower SNR than EPI, the STEAM technique completely avoided regional signal losses, high-intensity artifacts, and geometric distortions.

    Conclusions:

    • Subsecond DW single-shot STEAM MRI is a viable alternative to EPI for isotropic diffusion mapping.
    • This technique offers significant advantages by eliminating EPI-related artifacts, improving image quality and reliability.
    • The method enables rapid, high-quality diffusion imaging of the brain, potentially advancing diagnostic capabilities.