Related Experiment Video
Updated: Aug 9, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Transcatheter retrieval and repositioning of an Amplatzer device embolized into the left atrium
M Peuster1, R Boekenkamp, R Kaulitz
1Department of Pediatric Cardiology and Pediatric Intensive Care, Hannover Medical School, Hannover, Germany. peuster.matthias@mh-hannover.de
Abstract:
A transcatheter technique is described for stabilization and retrieval of an embolized Amplatzer device, which was inadvertently deployed in the left atrium of a 2-year-old girl with hemodynamically significant atrial septal defect within the fossa ovalis. Since surgery was not available for immediate device retrieval, transcatheter means were chosen to prevent embolization of the device into the mitral valve. After stabilizing the device by creating a guidewire circuit through the wire mesh of the right atrial disk, the Amplatzer device was repositioned through the interatrial defect by snaring the microscrew. No residual shunting and perfect device position was recorded during Doppler echocardiography directly after the procedure as well as 1, 2, and 120 days after the intervention. Cathet. Cardiovasc. Intervent. 51:297-300, 2000.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care