Related Experiment Videos
Characterization of firefighter exposures during fire overhaul
D M Bolstad-Johnson1, J L Burgess, C D Crutchfield
1City of Phoenix Personnel, AZ 85003, USA.
Summary
Firefighter exposures during overhaul are significant, with formaldehyde and carbon monoxide frequently exceeding safe limits. Respiratory protection is crucial during this phase, as carbon monoxide does not reliably indicate other harmful airborne contaminants.
Area of Science:
- Occupational Health and Safety
- Environmental Science
- Firefighter Research
Background:
- Limited data exists on firefighter exposures during the overhaul phase of structure fires.
- Firefighters often work without respiratory protection during overhaul, searching for hidden fires.
- Previous studies focused on fire suppression, not the post-fire inspection phase.
Purpose of the Study:
- To comprehensively characterize firefighter exposures to various airborne contaminants during the overhaul phase.
- To assess compliance with established occupational exposure limits during overhaul operations.
- To determine the efficacy of carbon monoxide as an indicator for other combustion products.
Main Methods:
- Conducted air monitoring during the overhaul phase of 25 structure fires in Phoenix.
- Collected personal and area samples for a range of chemicals including aldehydes, benzene, polynuclear aromatic hydrocarbons (PNA), and metals.
- Utilized gas analyzers for continuous monitoring of carbon monoxide (CO), hydrogen cyanide (HCN), nitrogen dioxide (NO2), and sulfur dioxide (SO2).
Main Results:
- Exceedances of ceiling values for acrolein, CO, formaldehyde, and glutaraldehyde were observed.
- Short-term exposure limits were exceeded for benzene, NO2, and SO2.
- Polynuclear aromatic hydrocarbon (PNA) concentrations exceeded recommended exposure limits on an additive effects basis.
Conclusions:
- Firefighter exposures to multiple hazardous substances during overhaul frequently exceed established limits.
- Respiratory protection is strongly recommended for firefighters during the overhaul phase.
- Carbon monoxide (CO) levels are not reliable indicators of other hazardous combustion products present during overhaul.