Related Experiment Video
Updated: Aug 8, 2026

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Preoperative evaluation of the radial forearm free flap patient with the objective Allen's test
D A Nuckols1, T T Tsue, E B Toby
1Department of Otolaryngology-Head and Neck Surgery, University of Kansas School of Medicine, Kansas City, Kansas 66160, USA.
Objective:
The conventional subjective Allen's test (SAT) can be problematic because of its subjective nature. The objective Allen's test (OAT) was used before surgery to reliably and objectively assess forearm vascular flow in anticipation of harvesting a radial forearm free flap (RFFF) for use in head and neck reconstruction.
Study Design And Setting:
Retrospective analysis of 65 patients undergoing both preoperative SAT and OAT was completed at the University of Kansas Medical Center between December 1994 and March 1998.
Results:
The sensitivity and specificity of the SAT compared with the sensitivity and specificity of the OAT were only 65% and 76%, respectively. In 40 patients with at least 1 forearm with a positive SAT, only 1 (2.5%) patient was found by OAT to have vasculature that would not have allowed safe RFFF harvest in either forearm. In contrast, of the 25 patients with equivocal or negative SAT results in both arms, 18 (72%) were found by OAT to be safe candidates for RFFF harvests.
Conclusions:
The OAT is an objective measure of forearm vascular flow and is superior to conventional SAT in RFFF donor-site selection.
More Related Videos
10:56Procurement and Perfusion-Decellularization of Porcine Vascularized Flaps in a Customized Perfusion Bioreactor
Published on: August 1, 2022
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease V: Postoperative Nursing Management