Related Experiment Video
Updated: Jul 10, 2026

Synthesis and Functionalization of Nitrogen-doped Carbon Nanotube Cups with Gold Nanoparticles as Cork Stoppers
Published on: May 13, 2013
Oxidation of nitric oxide in a two-stage chemical scrubber using dc corona discharge
1Beltran Associates, Inc., 1133 East 35th Street, Brooklyn, NY 11210, USA. yang1987@aol.com
Abstract:
The dc corona was studied as an alternative for NO oxidation in a two-stage chemical scrubber. The dc corona plasma reactor completely oxidized 150ppm of NO to NO2 in an air stream. The NO2 was further oxidized at a higher voltage. For some cases, the NO2 in the effluents of the plasma reactor was absorbed quantitatively by a caustic sodium sulfite aqueous solution in a 2l bubble column gas absorber. The outlet concentrations of both NO and NO2 from the plasma-scrubber combination system (corona-induced chemical scrubber) were below the detection limit of the chemiluminescent NOx analyzer.