Background:
Positron emission tomography imaging is gaining popularity as a noninvasive staging tool in non-small cell lung cancer. Nonmalignant processes can also affect radio-tracer uptake. This study seeks to identify factors associated with false-positive staging of mediastinal metastases.
Methods:
A retrospective review was performed of 100 patients with early stage non-small cell lung cancer referred for positron emission tomography scan evaluation. All had pathologic confirmation of their disease. Positron emission tomography scans, radiology records, operative reports, and pathology results were reviewed. Patients with positron emission tomography scans interpreted as positive for mediastinal involvement and negative pathology at operation were selected.
Results:
Seven patients were found to have a false-positive positron emission tomography evaluation for mediastinal metastases. All but 1 patient had a concurrent inflammatory process or an anatomic factor associated with the false positive. The sensitivity and specificity in detecting involved mediastinal nodes was 87.5% and 90.7%, respectively. The negative predictive value was 95.8%.
Conclusions:
Although positron emission tomography has been established as an accurate modality to stage non-small cell lung cancer, false-positive evaluation of mediastinal metastases can occur in the setting of concurrent inflammatory lung diseases or for centrally located tumors. Pathologic evaluation of mediastinal disease should be pursued whenever suggested by a positive positron emission tomography scan especially in the face of those factors described.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET