Related Experiment Video
Updated: Aug 9, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Reliability of Allen's test in selection of patients for radial artery harvest
M A Jarvis1, C L Jarvis, P R Jones
1Department of Cardiothoracic Surgery, Glenfield Hospital, Leicester, United Kingdom. martin-sie@cabg-jarvis.freeserve.co.uk
Background:
Allen's test is widely used to assess the ulnar collateral blood supply of the hand before radial artery harvest for coronary bypass surgery. This study was performed to determine the optimum cut-off point for a positive Allen's test and the clinical reliability of Allen's test in this role.
Methods:
Patients undergoing coronary artery bypass surgery were examined by independent observers using both Allen's test and a Doppler ultrasound test of the ulnar collateral circulation.
Results:
We examined 93 hands in 47 patients; mean age was 63.6 years. Receiver operating characteristic analysis found that at a conventional cut-off of 6 seconds on Allen's test had a sensitivity of 54.5%, specificity of 91.7%, and diagnostic accuracy of 78.5%. At a cut-off of 5 seconds diagnostic accuracy was maximal (79.6%), with sensitivity of 75.8% and specificity of 81.7%; 100% sensitivity occurred at a cut-off of 3 seconds, with specificity of 27% and diagnostic accuracy of 52%.
Conclusions:
At no cut-off point does Allen's test perform satisfactorily as a discriminatory test. It should be replaced by more objective tests, such as Doppler ultrasound.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Arteries of the Upper Limbs
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation