Background:
A thoracoscopic approach to coronary bypass grafting warrants renewed search for facilitated vascular anastomosis methods. We reassessed tissue adhesion, sealing properties, and histotoxicity of iso-butyl-cyanoacrylate, in a simplified anastomosis model.
Methods:
In 12 Dutch landrace pigs, five arteriotomies were made in each carotid artery. The arteriotomies were closed by conventional microvascular suturing or by pericardial patch (Peri-Strips) and iso-butyl-cyanoacrylate. The animals were sacrificed at 2 hours (n = 2), 2 days (n = 5), and 4 weeks (n = 5). The arteries were examined by flow measurement, angiography, and histologic analysis.
Results:
The time required to close arteriotomies by conventional suturing was 257 +/- 43 seconds (mean +/- SD) and by glued patch 51 +/- 27 seconds (p < 0.001). In all arteriotomies covered by glued patch, complete hemostasis was obtained. At 2 days and 4 weeks, with both methods the same histologic results were observed. At follow-up, all carotid arteries were patent without stenoses.
Conclusions:
Arteriotomy closure by glued patch was simple, fast, reliable, and without signs of histotoxicity. Adhesives deserve to be reconsidered as an alternative to suturing in closed chest beating-heart coronary surgery.