Procedure for Human Saphenous Veins Ex Vivo Perfusion and External Reinforcement
Published on: October 1, 2014
In vitro model of intravenous fluid administration: analysis of vein resistance to rapid fluid delivery
S Yaniv1, P Halpern, D Aladgem
1Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, 69978, Tel Aviv, Israel.
Abstract:
Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion into a vein-like compliant tube that (a) demonstrated the interdependence between fluid administration and blood flow in a compliant tube and (b) allowed investigation of the contribution of the central venous system (between the infusion site and the heart) to the total resistance to infusion flow rate. The results show that in cases with very high resistance in the central venous system a significant increase of infusion flow rate cannot be achieved just by increasing the infusion pressure. Similarly, in cases of small veins when only small catheters can be used, infusate flow rate may be increased only by using two independent infusion ports. In cases with increased tissue pressure due to edema, gravity-driven infusion may not produce sufficient perfusion of the vascular compartments. It was also shown that the vein valves do not always close, and that peripheral blood flow may continue together with the infusate fluid (e.g., when there is a small downstream resistance and infusion with a small catheter).
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Rapidly Varying Flow