Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High density collimated beams of relativistic ions produced by petawatt laser pulses in plasmas

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2000
Same author

Asymptotic evolution of nonlinear landau damping

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2000
Same author

Relativistic solitons in magnetized plasmas

Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics·2000
Same author

Impact of kinetic processes on the macroscopic nonlinear evolution of the electromagnetic-beam-plasma instability

Physical review letters·2000
Same author

Editorial comment

Head & neck·2000
Same author

Electron vortices produced by ultraintense laser pulses.

Physical review letters·1996

Related Experiment Video

Updated: Jul 22, 2026

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
11:20

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses

Published on: July 2, 2012

Induced plasma nonuniformities and wave vector cascade in the strong wave-plasma interaction

Lontano1, Califano

  • 1Istituto di Fisica del Plasma "Piero Caldirola," CNR, EURATOM-ENEA-CNR Association, Milan, Italy.

Physical Review. E, Statistical Physics, Plasmas, Fluids, and Related Interdisciplinary Topics
|November 23, 2000
PubMed
Summary

This study investigates how electrostatic waves interact with electron-ion plasmas. Nonlinear effects like wavebreaking and particle trapping are triggered by wave-induced plasma density changes.

More Related Videos

An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation
08:36

An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation

Published on: November 3, 2016

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

Related Experiment Videos

Last Updated: Jul 22, 2026

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
11:20

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses

Published on: July 2, 2012

An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation
08:36

An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation

Published on: November 3, 2016

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

Area of Science:

  • Plasma Physics
  • Computational Physics

Background:

  • Finite amplitude electrostatic waves can interact with plasmas.
  • Understanding these interactions is crucial for plasma dynamics.

Purpose of the Study:

  • To investigate the nonlinear interaction between electrostatic waves and an unmagnetized electron-ion plasma.
  • To explore the role of wave-induced plasma density nonuniformities.

Main Methods:

  • A one-dimensional kinetic code was used.
  • The Vlasov and Poisson equations were solved for plasma species and electric fields.

Main Results:

  • Nonlinear phenomena including wavebreaking and particle trapping were observed.
  • Electron heating and ion beam production were identified.
  • Plasma density nonuniformities were found to trigger these processes.

Conclusions:

  • Wave-induced plasma density nonuniformities are key triggers for nonlinear interactions.
  • These interactions lead to complex plasma behaviors like wavebreaking and particle trapping.