Objective:
To compare a number of electronic tympanic, oral, axillary, and rectal measurements with those taken with a standard rectal mercury thermometer.
Design:
Prospective open study.
Setting:
County hospital, Denmark.
Subjects:
200 patients.
Interventions:
Each of 200 patients had 6 electronic measurements of body temperature: 3 in the auditory canal using Ivac Core Check 2090A, Diateck 9000, and Genius 3000A, 1 in the axilla using Terumo Digital C202. 1 in the mouth using Terumo Digital C402, and 1 in the rectum using a Terumo Digital C402. These were compared with readings from a standard mercury glass thermometer in the rectum.
Main Outcome Measures:
Accuracy of electronic thermometry.
Results:
The rectal electronic measurements were closest to the rectal mercury readings, with a mean (SD) of -0.05 degrees C (0.12), whereas the other measurements gave unacceptable SDs of temperature differences ranging from 0.41 degrees C to 0.53 degrees C.
Conclusions:
We conclude that electronic rectal temperature measurements are the most accurate. We do not recommend electronic tympanic, oral, or axillary measurements.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...