Related Experiment Video
Updated: Aug 1, 2026

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Elimination of field size dependence of enhanced dynamic wedge factors
A Sethi1, L B Leybovich, N Dogan
1Department of Radiation Oncology, Loyola University Medical Center, Maywood, IL 60153, USA. asethi@rdth.rdth.luc.edu
Abstract:
Enhanced dynamic wedge factors (EDWF) are characterized by a strong field size dependence. In contrast to physical wedge factors, the EDWF decrease as the field size is increased: for 6 MV 60 degrees wedge, the EDWF decreases by 50% when the field size is increased from 4 x 4 cm2 to 20 x 20 cm2. A method that eliminates the field size dependence of EDWF was developed and investigated in this work. In this method, the wedged field shape is determined by a multileaf collimator. The initial position of the moving Y jaw is determined by the field size and the stationary Y jaw is kept fixed at 10 cm for field sizes < or = 20 cm in the wedged direction. For all other fields, the stationary Y jaw setting is determined by the field size. The modified method results in EDWF that are independent of field size, with no change in the wedge dose distribution when compared with the conventional use of EDW.
More Related Videos
07:57Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
Published on: November 10, 2014
11:51Visually Based Characterization of the Incipient Particle Motion in Regular Substrates: From Laminar to Turbulent Conditions
Published on: February 22, 2018
Related Concept Videos
Constraints and Statical Determinacy
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a decrease in the...
Indeterminate Structure
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...