Related Experiment Video
Updated: Aug 17, 2026

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
The carotid pulse check revisited: what if there is no pulse?
1Department of Anesthesiology, Johannes Gutenberg University Hospital, Mainz, Germany.
Abstract:
This study was undertaken to evaluate the diagnostic accuracy and time required by first responders to assess the carotid pulse in potentially pulseless patients. We conducted a prospective, randomized study of first responders (n = 206; four different training levels) and were blinded as to the patients' conditions in the cardiac operating rooms of a university hospital. Sixteen patients underwent coronary artery bypass surgery on nonpulsatile cardiopulmonary bypasses. Carotid pulse check was performed either during pulsatile (spontaneous) or during nonpulsatile (extracorporeal) circulation. Patients' hemodynamic status at the time of assessment, diagnostic accuracy of the first responders, and the time required to diagnose carotid pulsatility or pulselessness were documented. Within 10 secs, only 16.5% of the participants (34 of 206) were able to reach any decision about their patients' pulse status. Assessments that were both rapid and correct (15%, i.e., 31 of 206) occurred almost exclusively in pulsatile patients. Advanced training level shortened the delay to decision and improved its accuracy. However, merely 2% of the participants (1 of 59) correctly recognized a truly pulseless patient within 10 secs. Recognition of pulselessness of the carotid artery by rescuers with basic cardiopulmonary resuscitation training is time-consuming and highly inaccurate. Although the carotid pulse check needs to be taught, its importance in the context of layperson basic life support should be de-emphasized.
More Related Videos
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse Assessment Sites
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...