Quantifying X-Ray Fluorescence Data Using MAPS
Published on: February 17, 2018
The continuum normalization method for quantification of X-ray spectra in biological microanalysis. 1. Generalized
1Department of Physics & Astronomy, University of Glasgow, G12 8QQ, UK. p.nicholson@physics.gla.ac.uk
Abstract:
The thin self-supporting biological specimens used for quantitative X-ray microanalysis are problematical because the sections are most unlikely to be uniform in thickness or density, so the intensities of the characteristic lines alone are not a good measure of composition. The method developed to overcome these problems was introduced by T. A. Hall in 1971 and uses the bremsstrahlung or continuum intensity recorded in the X-ray spectrum to normalize each characteristic line, and hence is frequently referred to as the continuum normalization (CN) procedure. Reformulating the CN method of quantification in terms of generalized cross-sections and calculating more accurate values of bremsstrahlung production using a formula allows us a better understanding of the options open to the analyst of biological thin sections by which the errors in the measurement may be reduced. If one chooses to use the original Hall (1971) method using Kramers cross-sections, the window measuring the continuum for normalization should be set in the 4-7 keV region for typical scanning electron microscope and microprobe beam energies, 20-40 kV, and above 10 keV for transmission electron microscope energies of 80 kV and above. Although it is clear that peak counts must not contribute to the white count, the window should be as wide as possible to reduce statistical errors.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...