Related Experiment Videos
Chromatography of human prothrombin from Nitschmann fraction III on DEAE Sepharose Fast Flow using axial and radial
1Institute of Transfusion Medicine, PO Box 130(9), 27 TaiPing Road, Beijing 100850, People's Republic of China. sunt@cin.bmi.ac.cn
Biomedical Chromatography : BMC
|December 13, 2000
Abstract:
An axial column (3 x 2.6 cm) and a radial flow column (3.5 x 5 cm) packed with DEAE Sepharose Fast Flow media was evaluated for the separation of human prothrombin from Nitschmann fraction III. Under radial flow conditions, a sample flow rate up to 14 mL/min (approximately 18 bed vols/h) was achieved. Breakthrough capacity was determined and both columns had almost the same breakthrough capacity per mL media, indicating that the sample loading was independent of radial column geometry.