Related Experiment Video
Updated: Jan 4, 2026

Generation of Hypoparathyroid Rats via Carbon-Nanoparticle-Assisted Parathyroidectomy
Published on: July 14, 2023
Efficacy of preoperative dual-phase sestamibi scanning in hyperparathyroidism
C W Chang1, T T Tsue, A S Hermreck
1Department of Otolaryngology--Head and Neck Surgery, Vanderbilt, Nashville, TN, USA.
Purpose:
The objective of this article is to evaluate our experience with sestamibi scanning in patients with primary and secondary hyperparathyroidism.
Patients And Methods:
A retrospective review of patients referred to the radiology department at the University of Kansas Medical Center for parathyroid studies between January 1, 1993, and August 1, 1998, was done. Patients included in the study were those who underwent both dual-phase technetium (Tc-99m) sestamibi scanning and subsequent parathyroidectomy at our institution (n = 34). Twenty-six patients had primary hyperparathyroidism and 8 patients had secondary hyperparathyroidism. Fifteen had previous history of neck exploration.
Results:
Sensitivity of sestamibi scans in detection of all abnormal pathology in cases of primary hyperparathyroidism was 60% overall. Among the subset of adenoma cases, sensitivity was 82% (14/17). Among cases of primary parathyroid hyperplasia, no scan correctly localized all abnormal glands; however 60% (3/5) showed localization of at least one hyperplastic gland. Of the 2 patients with parathyroid carcinoma, in only one case was there evidence of sestamibi retention in the correct thyroid lobe. In patients with secondary hyperparathyroidism, sestamibi scanning was successful in identifying all hyperplastic tissue in only one case (sensitivity 13%). In 7 of the 8 cases of secondary hyperparathyroidism, the scan localized at least one hyperplastic gland.
Conclusion:
Sestamibi scanning is useful in the localization of abnormal pathology in cases of primary hyperparathyroidism, especially adenomas. In cases of hyperplasia, whether attributable to primary or secondary hyperparathyroidism, sestamibi imaging is less successful.
More Related Videos
07:12Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...