Blood flow in the external auditory canal and tympanic membrane as assess by laser doppler blood flowmetry
Abstract:
INTRODUCTION: Procedures within the external meatus and tympanum constitute a large part of otological surgery. Successful healing after procedures on the tympanic membrane will in large part be dependent on the integrity of local blood flow. However, there appear to have been relatively few studies investigating blood flow in the external auditory meatus and tympanum in normal subjects and those with conditions requiring surgery, e.g. tympanoplasty. The aim of this study is to obtain such data using Laser Doppler Blood Flowmetry. METHOD: Control volunteers (n = 30) and patients requiring tympanoplasty (n = 20) were recruited for the study. Laser Doppler Blood Flowmetry was performed in all patients using a commercially available system (Periflux 5000, Perimed AB, Sweden) at four sites: (1) preauricular skin; (2) cartilaginous ear canal; (3) bony ear canal; and (4) tympanic membrane. Mesotympanic temperature was also measured using a Braun Infrared thermometer. Blood flow (flux) was measured as RBC density 'speed following internal calibration. RESULTS: Analysis revealed that in both the control subjects and pretympanoplasty patients, the ranking of blood flow at the sites was 3, 2, 1 and 4 (highest to lowest). Comparing matched sites, there were no significant differences between the two groups. The amplitude of flow was not found to be correlated with mesotympanic temperature. CONCLUSION: Grafts applied to repair perforations of the tympanic membrane are likely to obtain the majority of their blood supply from the bony external auditory meatus rather than that tympanic membrane. Further studies are ongoing to define local blood flow patterns in order to optimize the results of tympanoplasty.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Anatomy of the Ear