Related Experiment Video
Updated: Jul 28, 2026

Quantifying Fish Swimming Behavior in Response to Acute Exposure of Aqueous Copper Using Computer Assisted Video and Digital Image Analysis
Published on: February 26, 2016
Determination of the taste threshold of copper in water
I Zacarías1, C G Yáñez, M Araya
1Institute of Nutrition and Food Technology, University of Chile, Macul 5540, PO Box 138-11, Santiago, Chile. izacaria@uec.inta.uchile.cl
Abstract:
Copper effects on human health represent a relevant issue in modern nutrition. One of the difficulties in assessing the early, acute effects of copper ingested via drinking water is that the taste of copper may influence the response and the capacity to taste copper in different waters is unknown. The purpose of the study was to determine the taste threshold of copper in different types of water, using soluble and insoluble salts (copper sulfate and copper chloride). Copper-containing solutions (range 1.0-8.0 mg/l Cu) were prepared in tap water, distilled deionized water and uncarbonated mineral water. Sixty-one healthy volunteers (17-50 years of age), with no previous training for sensory evaluation, participated in the study. A modified triangle test was used to define the taste threshold value. The threshold was defined as the lowest copper concentration detected by 50% of the subjects assessed. To evaluate the olfactory input in the threshold value obtained, 15 of 61 subjects underwent a second set of triangle tests with the nose open and clamped, using distilled water with copper sulfate at a concentration corresponding to the individual's threshold. The taste threshold in tap water was 2.6 mg/l Cu for both copper sulfate and copper chloride. The corresponding values for distilled deionized water were 2.4 and 2.5 mg/l Cu for copper sulfate and copper chloride, respectively. In uncarbonated mineral water the threshold values were slightly higher, 3.5 and 3.8 mg/l Cu for copper sulfate and for copper chloride, respectively, which are significantly higher than those observed in tap and distilled waters (P < 0.01, Kruskal-Wallis test). The taste threshold did not change significantly when the nose was clamped. In conclusion, the median values for copper taste threshold were low, ranging between 2.4 and 3.8 mg/l Cu, depending on the type of water.
Related Concept Videos
Determining the pH of Salt Solutions
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration Curve: Analysis
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation and Co-precipitation
Extraction: Advanced Methods

