Related Experiment Video
Updated: Aug 1, 2026

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing
A Celler1, T Farncombe, C Bever
1Vancouver Hospital and Health Sciences Centre, BC, Canada. aceller@physics.ubc.ca
Abstract:
Radionuclide imaging is now widely used whenever functional information is required. We present a new approach to dynamic SPECT imaging (dSPECT method) that uses a single slow rotation of a conventional camera and allows us to reconstruct a series of 3D images corresponding to the radiotracer distribution in the body at various times. Using simulations of various camera configurations and acquisition protocols, we have shown that this method is able to reconstruct washout half-lives with an accuracy greater than 90% when used with triple-head SPECT cameras. Accuracy decreases when using fewer camera heads, but dual-head geometries still give an accuracy greater than 80% for short and 90% for long half-lives and about 50-75% for single-head systems. Dynamic phantom experiments have yielded similar results. Presence of attenuation and background activity does not affect the accuracy of the dSPECT reconstructions. In all situations investigated satisfactory dynamic images were produced. A preliminary normal volunteer study measuring renal function was performed. The reconstructed dynamic images may be presented as a three-dimensional movie showing movement of the tracer through the kidneys and the measurement of the regional renal function can be performed. The time-activity curves determined from this dSPECT data are very similar to those obtained from dynamic planar scans.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET