Abstract:
Monitoring lung volume is important in the treatment of acute hypoxemic respiratory failure. However, there are no tools available for lung volume measurement to guide ventilator management during high-frequency oscillatory ventilation (HFOV) and during dynamic changes in conventional ventilation (CV). We studied the performance of a new respiratory inductive plethysmograph (RIP) with modified software. We measured Delta changes in lung volume above end-expiratory volume (V(RIP)) during HFOV and studied whether changes in V(RIP) parallel changes in mean airway pressure. Calibration of the plethysmograph was made by serial injections of a known gas volume in six term (140 d gestation) and eight preterm (125 d gestation) lambs. Linear regression analysis of the relationship between injected gas volume and V(RIP) showed strong correlation (r(2) = 0.93-1.00 term animals, r(2) = 0.86-1.00 preterm animals). The pressure volume curves from the calibration with the injected gas volumes also correlated well with the pressure volume curves extrapolated from changes in V(RIP). Lung hysteresis was clearly demonstrated with RIP after changes in mean airway pressure during HFOV and after changes in positive end-expiratory pressure during CV. We conclude that measurements of lung volume in term and preterm lambs by use of modified RIP correlate well with changes in mean airway pressure during HFOV, with static pressure volume curves and with changes in positive end-expiratory pressure during CV. We speculate that this technique may provide clinically useful information about changes in lung volume during HFOV and CV. However, evaluation of the precision and chronic stability of RIP measurements over prolonged periods will require further studies.
Related Concept Videos
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...