Related Experiment Video
Updated: Aug 8, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Muscle blood flow and flow heterogeneity during exercise studied with positron emission tomography in humans
K K Kalliokoski1, J Kemppainen, K Larmola
1Turku PET Centre, Finland. kari.kalliokoski@pet.tyks.fi
Abstract:
Blood flow is the main regulator of skeletal muscle's oxygen supply, and several studies have shown heterogeneous blood flow among and within muscles. However, it remains unclear whether exercise changes the heterogeneity of flow in exercising human skeletal muscle. Muscle blood flow and spatial flow heterogeneity were measured simultaneously in exercising and in the contralateral resting quadriceps femoris (QF) muscle in eight healthy men using H2(15)O and positron emission tomography. The relative dispersion (standard deviation/mean) of blood flow was calculated as an index of spatial flow heterogeneity. Average muscle blood flow in QF was 29 (10) ml x (kg muscle)(-1) x min(-1) at rest and 146 (54) ml x (kg muscle)(-1) x min(-1) during exercise (P = 0.008 for the difference). Blood flow was significantly (P < 0.001) higher in the vastus medialis and the vastus intermedius than in the vastus lateralis and the rectus femoris, both in the resting and the exercising legs. Flow was more homogeneous in the exercising vastus medialis and more heterogeneous (P < 0.001) in the exercising vastus lateralis (P = 0.01) than in the resting contralateral muscle. Flow was more homogeneous (P < 0.001) in those exercising muscles in which flow was highest (vastus intermedius and vastus medialis) as compared to muscles with the lowest flow (vastus lateralis and the rectus femoris). These data demonstrate that muscle blood flow varies among different muscles in humans both at rest and during exercise. Muscle perfusion is spatially heterogeneous at rest and during exercise, but responses to exercise are different depending on the muscle.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Blood Flow
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET