A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Initial clinical experience with a dual chamber rate responsive implantable cardioverter defibrillator
1rluceri@mediaone.net
The present study reports the first clinical experience with the Photon DR dual chamber rate responsive ICD. Fifty-seven patients (mean age 67.6 +/- 10 years) with a mean LVEF of 0.332 in NYHA Class I (30%), II (51%), or III (19%) met the implant criteria. Tachyarrhythmia diagnoses included VF (21%), VT (49%), or VT/VF (30%). Additional bradycardia pacing diagnoses included AV block (18%), sinus node dysfunction (5%), and sinus bradycardia (11%). All patients were followed on a long-term basis. A device-based direct current fibrillator (DC fibber) successfully induced VF in 96.2% of 243 attempted inductions. Detection times (2.86 +/- 0.47 s) and redetection times (1.29 +/- 0.32 s) compared favorably with historic controls using a morphology detection (MD) clinical data. Defibrillation energy and voltage thresholds were 10.4 +/- 5.5 J (range 3-28) and 421 V +/- 108 (range 230-696), respectively. Ninety-two clinical arrhythmias were recorded. Using a nominal nonindividualized algorithm, the sensitivity for VT detection was 100% and specificity for SVT rejection 81%. There were six patient deaths (2 nonsudden arrhythmic, 2 cardiac, 2 other). In conclusion, early clinical experience with the Photon DR ICD supports its safety, efficacy, and ability to provide advanced dual chamber ICD features.
The present study reports the first clinical experience with the Photon DR dual chamber rate responsive ICD. Fifty-seven patients (mean age 67.6 +/- 10 years) with a mean LVEF of 0.332 in NYHA Class I (30%), II (51%), or III (19%) met the implant criteria. Tachyarrhythmia diagnoses included VF (21%), VT (49%), or VT/VF (30%). Additional bradycardia pacing diagnoses included AV block (18%), sinus node dysfunction (5%), and sinus bradycardia (11%). All patients were followed on a long-term basis. A device-based direct current fibrillator (DC fibber) successfully induced VF in 96.2% of 243 attempted inductions. Detection times (2.86 +/- 0.47 s) and redetection times (1.29 +/- 0.32 s) compared favorably with historic controls using a morphology detection (MD) clinical data. Defibrillation energy and voltage thresholds were 10.4 +/- 5.5 J (range 3-28) and 421 V +/- 108 (range 230-696), respectively. Ninety-two clinical arrhythmias were recorded. Using a nominal nonindividualized algorithm, the sensitivity for VT detection was 100% and specificity for SVT rejection 81%. There were six patient deaths (2 nonsudden arrhythmic, 2 cardiac, 2 other). In conclusion, early clinical experience with the Photon DR ICD supports its safety, efficacy, and ability to provide advanced dual chamber ICD features.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy V: Interprofessional Care
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview