Related Experiment Videos
Systemic exposure to fluticasone propionate administered via metered-dose inhaler containing chlorofluorocarbon or
A E Mackie1, J E McDowall, P Ventresca
1Lilly Research Centre, Windlesham, Surrey, England.
Objective:
The pharmacokinetic profile of a single dose of inhaled fluticasone propionate (FP) administered via a metered-dose inhaler (MDI), containing either a chlorofluorocarbon (CFC) or hydrofluoroalkane (HFA) propellant was investigated in healthy volunteers.
Methods:
Two randomised, double-blind, crossover studies were conducted, each in 12 male volunteers. Both studies compared pharmacokinetic data after a single inhaled dose of FP 1000 microg from a MDI containing either CFC (CFC MDI) or HFA (HFA MDI) with a single intravenous dose of FP 250 microg.
Results:
The maximum plasma FP concentrations after inhalation via the 2 types of MDI were almost identical (0.56 and 0.54 microg/L for CFC MDI and HFA MDI, respectively); bioavailability values of inhaled FP from the 2 MDIs were also similar (geometric mean values: 26.4% via the CFC MDI and 28.6% via the HFA MDI). Inhalation of FP via both MDI formulations produced similar reductions in urinary cortisol excretion over 12 and 24 hours postdose.
Conclusion:
The bioavailability values of FP after inhalation via a CFC MDI and an HFA MDI are similar. The 2 formulations deliver comparable amounts of FP, and systemic exposures to FP from the 2 devices, measured by urinary cortisol excretion, are not significantly different.